E | With rubber stop, locking device in retracted position |
2 | Mounting with countersunk holes |
l1 | l2 +0.16 / -0.16 Stroke | l3 | Fs per pair at 10,000 cycles | at 100,000 cycles |
---|---|---|---|---|
15.75 | 17.13 | 32.87 | 353 lbf (1570 N) | 218 lbf (970 N) |
17.72 | 19.09 | 36.81 | 360 lbf (1600 N) | 232 lbf (1030 N) |
19.69 | 21.46 | 41.14 | 380 lbf (1690 N) | 259 lbf (1150 N) |
21.65 | 23.43 | 45.08 | 420 lbf (1870 N) | 261 lbf (1160 N) |
23.62 | 25.59 | 49.21 | 425 lbf (1890 N) | 265 lbf (1180 N) |
27.56 | 29.53 | 57.09 | 420 lbf (1870 N) | 308 lbf (1370 N) |
31.50 | 33.46 | 64.96 | 477 lbf (2120 N) | 330 lbf (1470 N) |
35.43 | 37.40 | 72.83 | 432 lbf (1920 N) | 281 lbf (1250 N) |
39.37 | 41.34 | 80.71 | 402 lbf (1790 N) | 243 lbf (1080 N) |
47.24 | 49.21 | 96.46 | 366 lbf (1630 N) | 214 lbf (950 N) |
Show / Hide columns
|
Show / Hide columns
|
For the listed loading forces FS to be absorbed reliably in the surrounding structure, all available countersunk holes of the outer and inner slide must be used. Failure to use mounting screws reduces the specified load capacity accordingly. The following screws can be used for mounting: |
|||||||||||
Designation - Standard |
Outer Slide |
Inner Slide |
The maximum load capacity of telescopic slides depends on the slide cross-section and the nominal length l1 as well as the resulting stroke l2. Furthermore, the extension width, the slide materials used and the components of the equipment options, such as the dampened self-retracting mechanism, have a corresponding influence. |
|||||||||||
|
|||||||||||
Wear, performance, and maximum bending were assessed after each test section. |
Min | Max | Price |
---|---|---|
1 | 4 | $128.54 |
5 | 9 | $117.83 |
10 | 24 | $107.12 |
≥ 25 | $96.41 |
Our service team is available from Monday to Friday between 7:30 AM and 5:00 PM Central Time: 800-877-8351
We are grateful for our customers, partners, suppliers and JW Winco team!